Guides / Process
How Machined Brass Valve Bodies Are Leak Tested and Pressure Tested
Published November 13, 2026. Reviewed for the facts in the corrections log.

Machined brass valve bodies are tested with air or water at a set multiple of rated pressure. A bubble test finds gross leaks, pressure decay measures small ones and helium finds the smallest. The product standard sets the pressure, the hold time and the allowed leak rate, so name it on the drawing.
A valve body is a pressure vessel with a hole for the flow and a stem. If the wall leaks to the outside the valve has failed before it reaches the customer, and a leak across the seat means the valve cannot do the one thing it is for. That is why valve bodies are tested at pressure on every lot, and often on every part.
This post covers the main test methods, what each one can and cannot find, and what a buyer should put on a drawing so that the shop tests what the product standard needs.
Two tests, not one
Valve standards separate two checks. The shell test pressurises the body with the ends blanked and looks for leaks through the wall, the joints and the stem seal. The seat test closes the valve, pressurises one side and measures what gets past the seat.
A machined body drawing mainly concerns the shell test. The seat test depends on the finished valve with its ball, seat and stem fitted, which is often done by the valve maker. But a body that fails the shell test never gets that far, and a body with a scratched seat face fails the seat test. Both feed back to the machining.
Many valve standards use a shell pressure of about 1.5 times the rated pressure and a seat pressure of about 1.1 times, held for a set time. EN 12266-1 and API 598 both follow this pattern for industrial valves, with different details. The product standard for your valve gives the exact figures. A machine shop does not choose them.
The test methods
| Method | What it uses | Typical sensitivity | Best for |
|---|---|---|---|
| Bubble test | Air inside the part, part under water | Roughly 1 bubble a second, about 0.001 to 0.01 mbar l/s | Gross leaks, quick sorting, finding the leak point |
| Hydrostatic test | Water at test pressure, visual check | Visible weeping | Shell strength on larger bodies, safety |
| Pressure decay | Air, sealed volume, pressure drop over time | About 0.1 to 1 cc/min in a good setup | Series production, a number on every part |
| Mass flow | Air, measures flow needed to hold pressure | About 0.1 to 1 cc/min | Faster cycle than decay on large volumes |
| Helium | Helium inside, sniffer or vacuum chamber | 0.000001 mbar l/s and below | Refrigerant, gas and critical service |
Published typical values for the methods. Real sensitivity depends on volume, temperature, fixture and operator, and the standard being tested to takes precedence.
Bubble test. The body is pressurised with air and lowered into a water tank. A stream of bubbles marks the leak. It is cheap, it needs no calibration and the operator sees where the leak is. It depends on the operator, so it is hard to compare between shifts, and a small leak can hide until the part has soaked.
Hydrostatic test. The body is filled with water, pressurised and checked visually. Water stores very little energy, so a failure is a spill and not a burst. It is the traditional shell test. It leaves the part wet, so parts must be dried before assembly or plating.
Pressure decay. The fixture seals the body, fills it with air, closes the supply and watches the pressure fall. A pass is a pressure drop below a set limit inside a set time, typically 5 to 20 seconds after a stabilisation period. It gives a number for each part and is easy to automate. It is sensitive to temperature, because compressing air warms it and the pressure falls as it cools. That is why a stabilisation time comes before the measuring time.
Helium. Where an air test is not enough, as with refrigerant, medical gas or fuel gas valves in some markets, helium finds leaks orders of magnitude smaller. The part is filled with helium and a mass spectrometer reads what escapes. It costs far more per part, so shops use it only when the specification demands.
Where brass bodies leak
Dimensional inspection rarely finds the causes of a leak. They sit in the metal and on the sealing faces.
Porosity. Cast brass bodies can contain small gas voids and shrinkage cavities. When a cutter opens one, a path to the bore appears. Forged bodies from C377 forging brass are dense by comparison, and bodies turned from bar are dense throughout, but cost more in material. The trade is covered in machined vs cast brass parts.
Burrs and scratches. A burr that lifts under pressure or a scratch across a sealing face makes a leak path that no gauge on the diameters will show. Deburring cross holes explains the usual trouble spots.
Cross holes and thread roots. A drilled cross hole can break into a neighbouring passage, and a thread cut too deep can run into a thin wall. Wall thickness near the thread should be checked at the first article.
O-ring grooves. A groove cut too deep or too wide, or with a rough finish, leaks even with a good O-ring. See O-ring grooves in brass.
Chips and contamination. A chip sitting on a sealing face or a film of cutting oil confuses the test. Parts should be clean and dry before testing.
Need a quote for this part? Get a quote for your brass parts
Test fixtures
The fixture is part of the test. Seals that close the body ends must not leak themselves, or the test reads the fixture and not the part. A fixture that clamps the part too hard can distort a thin wall and hide a leak. A fixture that uses the part’s own thread can damage it. Shops keep a calibrated leak standard, a part with a known small hole, and run it at the start of each shift to prove the setup can find a leak. A shop that cannot show that check cannot say its test works.
Test pressure and medium on the drawing
A typical set of drawing notes:
Shell test: air at 10 bar, hold 20 s, no bubbles under water (or decay under 0.5 cc/min).
Test every part. Parts to be clean and dry before test.
Test per product standard, edition as stated on the purchase order.
Or for a water valve:
Hydrostatic shell test at 1.5 times rated pressure, hold 30 s, no visible leakage.
Write the medium, the pressure, the hold time, the acceptance rule and whether every part is tested or a sample. If the valve is for drinking water, add the lead requirement as well. See NSF 61 and NSF 372 brass fittings for how that is worded.
Records and traceability
A test is only worth what the record shows. For valve bodies headed for regulated markets, ask the shop to keep the test result with the lot: the fixture used, the pressure, the hold time, the reject count and the date of the last leak standard check. On automated pressure decay stations the machine logs a result for every part, and a shop can send a summary with the shipment. For a bubble test a signed lot sheet is the usual record. Rejected parts should be marked and held apart, never reworked and retested without a note, since a part re-cut near a sealing face is a different part from the one the first test judged.
Safety
Air at pressure stores energy and a failed part can throw fragments. Test cells need a guard or a cage. Do not test a brass body with air at a pressure above what the fixture and part are rated for, and do not hold a part in the hand during a pressure test. Water tests at the same pressure are much safer.
Checklist
- Product standard named, with its edition.
- Shell test and seat test separated on the drawing.
- Medium, pressure, hold time and acceptance rule written out.
- Every part or sample, stated.
- Cleanliness and drying before test stated.
- Leak standard check at the start of each shift requested.
- Porosity rules for cast or forged bodies agreed with the shop.
When you are ready to quote a valve body, send the drawing with the test notes. We quote the finished parts within 24 business hours and place the work with one of the partner shops that turn brass.
Frequently asked questions
What pressure should a brass valve body be tested at?
The valve product standard sets it, not the machine shop. Many valve standards test the shell at about 1.5 times the rated pressure and the seat at about 1.1 times, held for a stated time. Copy the figures from the standard your valve is sold to and put them on the drawing with the test medium.
Is an air test or a water test better for brass bodies?
Water is safer, because a failed part stores little energy, and it shows leaks that weep. Air finds smaller leaks per unit of pressure and leaves the part dry, but it stores more energy and needs a guard. Gas valves are usually tested with air or nitrogen, and water valves with water or air.
Why do machined brass bodies leak after passing machining inspection?
Most leaks come from three places. Porosity can open when a cast or forged body is cut into. A burr or scratch can sit across a sealing face. A cross hole or thread root can break through to another passage. Dimensional inspection rarely finds these, which is why the pressure test is a separate step.
Alloys in this guide
| Alloy | Lead % | Mach. | DZR |
|---|---|---|---|
| C377 forging brassC37700 · CuZn39Pb2 / CW612N | 1.5 to 2.5 | 80 | Poor |
| C360 free-cutting brassC36000 · CuZn36Pb3 / CW603N | 2.5 to 3.7 | 100 | Poor |
Published typical values for the alloy. Machinability against C360 at 100. Not a promise from a shop.
Sources
- Wikipedia, Leak detection en.wikipedia.org
- Wikipedia, Hydrostatic test en.wikipedia.org
Need a quote for this part?
Send the drawing. We read it, send one itemised quote for the finished parts within 24 business hours and place the work with a partner shop that turns brass. Brass only.
Get a quote for your brass parts